Hot water pipe leaking under a utility room slab, Grimsby
The kitchen floor was saturated. Thermal imaging marked two areas, an air test showed the pipe held nothing, and opening the utility room slab found a corroded pipe.

- Location
- Grimsby, Lincolnshire (DN33)
- Property
- Large semi-detached house
- System
- Hot and cold copper pipes buried in concrete floors
- First sign
- Hot water pipe from under the boiler leaking; very high moisture in the kitchen floor
- Engineer
- Robert Gires, ADI Leak Detection
- Outcome
- Leak found under the slab; repaired in copper; re-pipe recommended
What was happening
The hot water pipe running from under the boiler had developed a leak, raising concern about water getting into the kitchen floor and the utility room behind the washing machine.
The pipes run under concrete floors, so nothing could be seen.
How the leak was traced
Thermal imaging
Traced the hot water pipe route and showed two areas of concern: behind the washing machine in the utility room, and the kitchen floor.
Damp meter
Very high readings in the kitchen floor.
Air pressure test
A compressor on the hot water pipework showed it could not hold any pressure: a substantial failure, not a small seep.
Visual inspection
After opening up, both the hot and cold pipes could be seen.
What was found
Under the kitchen unit both the hot and cold pipes were in very poor condition.
The active leak was on the hot water pipe under the utility room slab.
What happened next
The damaged section was cut out and replaced in copper.
Because of the state of both pipes, the engineer recommended replacing the pipework, since further failures are likely.
What else the floor tells you
Opening a slab shows the condition of the pipes as well as the leak. Here it told the owner the repair would not be the last one unless the old pipework was replaced.
Photos from the job

Damp meter at the top of its scale on the kitchen floor. 
Pressure testing the hot water pipework. 
Corroded pipework exposed under the slab. 
Corrosion and a pinhole on the removed copper. 
New copper fitted in the utility room.
Case published by ADI Leak Detection. Photos taken by the engineer during the investigation.